Hospital Nebulizers

Hikoneb 908 DC

Hikoneb 908 DC is a hospital-type ultrasonic nebulizer with an aluminum and stainless steel housing. The timer of Hikoneb 908 DC can be set up to 90 minutes, and the chamber volume is 650 ml.

Weight
4 kg
Power
70 W
Hikoneb 908 DC

How does Hikoneb 908 DC work?

Hikoneb 908 DC breaks the liquid into particles of 0.5-6 µm with a crystal frequency of 1.7 MHz. The nebulization capacity is 0-5 ml/min.

Automatic heating raises the vapor temperature up to 38 °C; the vapor output is constant.

How is Hikoneb 908 DC adjusted?

Hikoneb 908 DC is microprocessor-controlled and operated with 3 buttons on a digital panel. Vapor capacity, air output, heating and the timer are set from this panel.

The timer can be set up to 90 minutes. Hikoneb 908 DC gives a visual and audible alarm when the water runs out and in case of a fault; the oscillator has heat protection.

Which accessories come with Hikoneb 908 DC?

Hikoneb 908 DC is sold with Hytrel hoses, an additional water bottle, a bacteria and air filter, a trolley, a heater and a movable arm. An oxygen adapter is also available.

The polycarbonate chamber is 650 ml and the additional water bottle is 1000 ml. All parts that come into contact with the patient can be autoclaved at 132 °C.

For small-volume medication delivery, the medication volume is 5-7 ml. The oscillator crystal can be replaced easily.

What are the technical specifications of Hikoneb 908 DC?

SpecificationValue
Operating voltage220 V / 50 Hz
Crystal frequency*1.7 MHz
Power70 W
Particle size0.5-6 µm
Nebulization capacity0-5 ml/min
Chamber volume650 ml
Weight4 kg
Type / ClassBF/I
Medication deliverySmall volume (5-7 ml)
TimerAdjustable up to 90 min
AlarmVisual and audible alarm
Oscillator heat protectionYes
FilterDual filter system
HousingAluminum and stainless steel
Movable arm mechanismYes
SettingsVapor, air and temperature are adjustable
Hikoneb 908 DC technical specifications

The standard crystal frequency is 1.7 MHz; 2.4 MHz is offered as an option.

What is the difference between Hikoneb 908 DC and Hikoneb 906 S/LCD?

The housing of Hikoneb 908 DC is aluminum and stainless steel, and the timer is 90 minutes. Hikoneb 906 S/LCD has an ABS housing and an LCD screen, and the timer is 120 minutes.

Documents

Documents, grouped by language
Document Type Language Size
English (EN)
908-DC-ULTRASONIC-NEBULIZER Catalogue English (EN)

Products in the same family

  • Hikoneb 906 S/LCD

    Hikoneb 906 S/LCD

    Hikoneb 906 S/LCD is a hospital-type ultrasonic nebulizer with an LCD screen and an ABS housing. The timer of Hikoneb 906 S/LCD can be set up to 120 minutes, and the chamber volume is 650 ml.